Mean Well RS-100-24 24V100W AC/DC Switching Power Supply[481]

★★★★★(554 recommends)

SKUPS-SP11546

34.90

Add To Cart
Buy Now

+

Description

This power supply is ideally suited for use with amplifier projects. The regulated 24 VDC, 4.5A design is capable of delivering 100watts of output. Overload, over voltage, and short circuit protection is built-in, shutting down the power supply to prevent damage and then restoring power upon recovery.

  • TypeAD/DC Power
  • StyleEnclosed
  • Output ChannelSingle
  • Universal AC input/ Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105°C long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70°C
  • Withstand 5G vibration test
  • No load power consumption < 0.5W
  • High efficiency, long life and high reliability
MODELRS-100-24
OUTPUTDC VOLTAGE24V
RATED CURRENT4.5A
CURRENT RANGE0 ~ 4.5A
RATED POWER108W
RIPPLE & NOISE(max.) (Note.2)120mVp-p
VOLTAGE ADJ. RANGE22.8 ~ 26.4V
VOLTAGE TOLERANCE (Note.3)±1.0%
LINE REGULATION (Note.4)±0.5%
LOAD REGULATION (Note.5)±0.5%
SETUP, RISE TIME500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME(Typ.)100ms/230VAC  18ms/115VAC at full load
INPUTVOLTAGE RANGE88 ~ 264VAC  125 ~ 373VDC(Withstand 300VAC surge for 5 sec. Without damage)
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY(Typ.)84%
AC CURRENT(Typ.)2.5A/115VAC  1.5A/230VAC
INRUSH CURRENT(Typ.)COLD START 40A/230VAC
LEAKAGE CURRENT<2mA/240VAC
PROTECTIONOVERLOAD110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE27.6 ~ 32.4V
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENTWORKING TEMP.-25 ~ +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85°C, 10 ~ 95%RH
TEMP. COEFFICIENT±0.03%/°C (0 ~ 50°C)
VIBRATION10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC(Note.6)SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved
WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms/ 500VDC / 25°C / 70% RH
EMC EMISSIONCompliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25°C of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation.4. Line regulation is measured from low line to high line at rated load.5. Load regulation is measured from 0% to 100% rated load.6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC test, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.