Description
This power supply is ideally suited for use with amplifier projects. The regulated 24 VDC, 1.1A design is capable of delivering 25watts of output. Overload, over voltage, and short circuit protection is built-in, shutting down the power supply to prevent damage and then restoring power upon recovery.
- TypeAD/DC Power
- StyleEnclosed
- Output ChannelSingle
- Universal AC input/ Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- All using 105°C long life electrolytic capacitors
- Withstand 300VAC surge input for 5 second
- High operating temperature up to 70°C
- Withstand 5G vibration test
- No load power consumption < 0.5W
- High efficiency, long life and high reliability
MODEL | RS-25-24 | |
OUTPUT | DC VOLTAGE | 24V |
RATED CURRENT | 1.1A | |
CURRENT RANGE | 0 ~1.1A | |
RATED POWER | 26.4W | |
RIPPLE & NOISE(max.) (Note.2) | 120mVp-p | |
VOLTAGE ADJ. RANGE | 22 ~ 27.6V | |
VOLTAGE TOLERANCE (Note.3) | ±1.0% | |
LINE REGULATION (Note.4) | ±0.5% | |
LOAD REGULATION (Note.5) | ±0.5% | |
SETUP, RISE TIME | 1800ms, 23ms/230VAC 4000ms, 30ms/115VAC at full load | |
HOLD UP TIME(Typ.) | 80ms/230VAC 14ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 88 ~ 264VAC 125 ~ 370VDC(Withstand 300VAC surge for 5 sec. Without damage) |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY(Typ.) | 86% | |
AC CURRENT(Typ.) | 0.7A/115VAC 0.4A/230VAC | |
INRUSH CURRENT(Typ.) | COLD START 30A/230VAC | |
LEAKAGE CURRENT | <2mA/240VAC | |
PROTECTION | OVERLOAD | 110 ~ 180% rated output power |
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 27.6 ~ 32.4V | |
Protection type: Shut down o/p voltage, clamping by zener diode | ||
ENVIRONMENT | WORKING TEMP. | -20 ~ +70°C (Refer to “Derating Curve”) |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +85°C, 10 ~ 95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | |
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY & EMC(Note.6) | SAFETY STANDARDS | UL60950-1, TUV EN60950-1 , CCC GB4943 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/ 500VDC / 25°C / 70% RH | |
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3, GB9254 class B,GB17625.1 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11,light industry level, criteria A | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25°C of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation.4. Line regulation is measured from low line to high line at rated load.5. Load regulation is measured from 0% to 100% rated load.6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC test, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com) |