Description
This product is a 240W AC/DC LED driver featuring the dual modes constant voltage and constant current output. Thanks to its high efficiency, it is able to operate for -40 ~ +90°C case temperature under free air convection. The design of metal housing and IP67/65 ingress protection level allows it to fit both indoor and outdoor applications. This product is equipped with various function options, such as dimming methodologies so as to provide the optimal design flexibility for LED lighting system.
- TypeLED Driver
- StyleLED Driver
- Output ChannelSingle
- Constant Voltage + Constant Current mode output
- Metal housing with class I design
- IP67/IP65 rating for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming
- Typical lifetime > 62,000 hours
MODEL | HLG-240H-24A | |
OUTPUT | DC VOLTAGE | 24V |
CONSTANT CURRENT REGION (Note.4) | 12 ~ 24V | |
RATED CURRENT | 10A | |
RATED POWER | 240W | |
RIPPLE & NOISE(max.) (Note.2) | 150mVp-p | |
VOLTAGE ADJ. RANGE | Adjustable for A/C-Type only(via built-in potentiometer) | |
22.4 ~ 25.6V | ||
CURRENT ADJ. RANGE | Adjustable for A/C-Type only(via built-in potentiometer) | |
5 ~ 10A | ||
VOLTAGE TOLERANCE(Note.3) | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±0.5% | |
SETUP, RISE TIME(Note.6) | 1000ms, 80ms/115VAC 500ms, 80ms/230VAC | |
HOLD UP TIME(Typ.) | 15ms/115VAC, 230VAC | |
INPUT | VOLTAGE RANGE(Note.5) | 90 ~ 305VAC 127 ~ 431VDC (Please refer to “STATIC CHARACTERISTIC’ section) |
FREQUENCY RANGE | 47 ~ 63Hz | |
POWER FACTOR(Typ.) | PF≧0.98/115VAC, PF≧0.95/230VAC@ full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) | |
TOTAL HARMONICDISTORTION | THD< 20% (@ load≧50% / 115VAC,230VAC; @ load≧75%/277VAC) (Please refer to "TOTAL HARMONIC DISTORTION (THD)" section) | |
EFFICIENCY(Typ.) | 92.5% | |
AC CURRENT(Typ.) | 4A/115VAC 2A/230VAC 1.2A/277VAC | |
INRUSH CURRENT(Typ.) | COLD START 75A(twidth=570μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 2 units(circuit breaker of type B)/4 units(circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <0.75mA/277VAC | |
PROTECTION | OVER CURRENT | 95 ~ 108% |
Constant current limiting, recovers automatically after fault condition is removed | ||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |
OVER VOLTAGE | 27 ~ 34V | |
Shut down and latch off o/p voltage, re-power on to recover | ||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |
ENVIRONMENT | WORKING TEMP. | Tcase=-40 ~ +90°C (Please refer to "OUTPUT LOAD vs TEMPERATURE" section) |
MAX. CASE TEMP. | Tcase= +90°C | |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +80°C, 10 ~ 95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | |
VIBRATION | 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes | |
SAFETY & EMC | SAFETY STANDARDS | UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750(type”HL”), CSA C22.2 No. 250.0-08; TUV EN61347-1, EN61347-2-13 independent(except for HLG-240H C type); UL60950-1, UL8750, TUV EN60950-1;GB19510.1,GB19510.14; IP65 or IP67;J61347-1, J61347-2-13 approved |
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25°C/70% RH | |
EMC EMISSION | Compliance to EN55015, EN55032 (CISPR32) Class B, EN61000-3-2 Class C (@ load≧50%) ; EN61000-3-3, GB17743 and GB17625.1 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV) | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 °C of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation.4. Please refer to “DRIVING METHODS OF LED MODULE.”5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.9. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particular TC point(or TMP, per DLC), is about 75°C or less. 10. Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com. |