Description
This Mean Well LED Driver is ideally suitable for LED lighting and moving sign applications. This LED Driver is capable of delivering 150watts output. It is IP65 rated, which means its output voltage and constant current level can be adjusted through internal potentiometer. Power input is world compatible and able to work with universal AC input, even up to 295VAC. Over load, over voltage, over temperature and short circuit protection is built in to ensure its reliability.
- TypeLED Driver
- StyleLED Driver
- Output ChannelSingle
- Universal AC input/Full range(up to 295VAC)
- Built-in active PFC function
- High efficiency up to 91%
- Protections: Short circuit / Overload / Over voltage/Over temperature
- Cooling by free air convection
- OCP point adjustable through output cable or internal potentiometer
- IP65/IP67 designed for indoor or outdoor installations
- Suitable for LED lighting and moving sign applications
- Compliance to worldwide safety regulations for lighting
MODEL | CLG-150-12A | |
OUTPUT | DC VOLTAGE | 12V |
CONSTANT CURRENT REGION(Nore.4) | 9 ~ 12V | |
RATED CURRENT | 11A | |
RATED POWER | 132W | |
RIPPLE & NOISE(max.) (Note.2) | 150mVp-p | |
VOLTAGE ADJ. RANGE (Note.6) | 9 ~ 13V | |
CURRENT ADJ. RANGE | Can be adjusted by internal potentiometer A type and C type only | |
5.5 ~ 11A | ||
VOLTAGE TOLERANCE(Note.3) | 21.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±1.0% | |
SETUP, RISE TIME | 3000ms, 80ms 115VAC500ms, 80ms/230VAC at full load | |
HOLD UP TIME(Typ.) | 50ms/230VAC 16ms/115VAC at full load | |
INPUT | VOLTAGE RANGE(Note.5) | 90 ~ 295VAC 127 ~ 417VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
POWER FACTOR(Typ.) | PF>0.98/115VAC,PF>0.95/230VAC,PF>0.93/277VACat full load (Please refer to "Power Factor Characteristic" curve) | |
TOTAL HARMONIC DISTORTION | THD<20% when output loading≧75% at 115VAC/230VAC input and output loading≧75% at 277VAC input | |
EFFICIENCY(Typ.) | 88% | |
AC CURRENT(Typ.) | 2A/115VAC 1A/230VAC 0.68A/277VAC | |
INRUSH CURRENT(max.) | COLD START 65A(twidth=595μs measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 3 units(circuit breaker of type B)/5 units(circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | <1mA/240VAC | |
PROTECTION | OVER CURRENT(Typ.) (Note.4) | 95% ~ 108% |
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||
SHORT CIRCUIT | Hiccup mode, recovers automatically after fault condition is removed | |
OVER VOLTAGE | 13.5~ 17V | |
Protection type: Shut off and latch off o/p voltage, re-power on to recover | ||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |
ENVIRONMENT | WORKING TEMP. | -30 ~ +70°C (Refer to “Derating Curve”) |
WORKING HUMIDITY | 20 ~ 95% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +80°C, 10 ~ 95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | |
VIBRATION | 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes | |
SAFETY & EMC | SAFETY STANDARDS(Note.7) | Ul8750, CSA C22.2 No. 250.0-08, UL1012, CAN/CSA-C22.2 No. 107.1-01, UL879, CSA C22.2 No.207-M89, EN61347-1, EN61347-2-13 independent(except for CLG-150 C type),UL60950-1, TUV EN60950-1,GB19510.1,GB19510.14(for Blank & A type only), IP65 or IP67, J61347-1, J61347-2-13(except for CLG-150C type) approved |
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C / 70% RH | |
EMC EMISSION | Compliance to EN55015, EN55032 Class B, EN61000-3-2 Class C (≧75% load) ; EN61000-3-3,GB17743 and GB17625.1 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV) | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25°C of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation.4. Please refer to “DRIVING METHODS OF LED MODULE.”5. Derating may be needed under low input voltage. Please check the static characteristics for more details.6. A type and C type only.7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part 18.8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains. |