Mean Well CLG-100-36 26V 100W IP67 LED Driver[75]

★★★★★(243 recommends)

SKUPS-SP11351

69.90

Add To Cart
Buy Now

+

Description

This Mean Well LED Driver is ideally suitable for LED lighting and moving sign applications. This LED Driver is capable of delivering 100watts output. It has built-in active PFC function and IP67 design for indoor or outdoor installations. Power input is world compatible and able to work with universal AC input, and even up to 295VAC. Over load, over voltage, over temperature and short circuit protection is built in to ensure its reliability.

  • TypeLED Driver
  • StyleLED Driver
  • Output ChannelSingle
  • Universal AC input/Full range(up to 295VAC)
  • Built-in active PFC function
  • High efficiency up to 88.5%
  • Protections: Short circuit / Overload / Over voltage/Over temperature
  • Cooling by free air convection
  • IP67 designed for indoor or outdoor installations
  • Class 2 power unit
  • Pass LPS
  • 100% full load burn-in test
  • High reliability
  • Suitable for LED lighting and moving sign applications
  • •Compliance to worldwide safety regulations for lighting
  • Suitable for dry/damp/wet locations
MODELCLG-100-36
OUTPUTDC VOLTAGE36V
CONSTANT CURRENT REGION(Note.7)27 ~ 36V
RATED CURRENT(Note.5)2.65A
RATED POWER(Note.5)95.4W
RIPPLE & NOISE(max.) (Note.2)150mVp-p
VOLTAGE ADJ. RANGEFixed. Can be modified between 0% ~ -15% rated output voltage
CURRENT ADJ. RANGEFixed. Can be modified between 3% ~ -25% rated output current
VOLTAGE TOLERANCE (Note.3)±3.0%
LINE REGULATION ±1.0%
LOAD REGULATION ±2.0%
SETUP, RISE TIME(Note.6)500ms, 80ms 230VAC1200ms, 80ms/115VAC at full load
HOLD UP TIME(Typ.)60ms/230VAC   30ms/115VAC at full load
INPUTVOLTAGE RANGE(Note.4)90 ~ 295VAC  127 ~ 471VDC
FREQUENCY RANGE47 ~ 63Hz
POWER FACTOR(Typ.)PF>0.95/115VAC,PF>0.95/230VAC,PF>0.92/277VACat full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTIONTHD<20% when output loading≧75% at 115VAC/230VAC input and output loading≧75% at 277VAC input
EFFICIENCY(Typ.)88%
AC CURRENT(Typ.)12V:0.8A/115VAC,0.4A/230VAC,0.3A/277VAC 15V:0.9A/115VAC, 0.45A/230VAC, 0.35A/277VAC20V~48V:1.1A/115VAC0.55A/230VAC 0.45A/277VAC
INRUSH CURRENT(Typ.)COLD START 40A(twidth=1030μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER3 units(circuit breaker of type B)/5 units(circuit breaker of type C) at 230VAC
LEAKAGE CURRENT<0.75mA/240VAC
PROTECTIONOVER CURRENT(Typ.)95% ~ 102%
Protection type: Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUITHiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE39 ~ 48V
Protection type: Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATUREShut down o/p voltage, re-power on to recover
ENVIRONMENTWORKING TEMP.-30 ~ +70°C (Refer to “Derating Curve”)
WORKING HUMIDITY20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +80°C, 10 ~ 95%RH
TEMP. COEFFICIENT±0.03%/°C (0 ~ 50°C)
VIBRATION10 ~ 500Hz, 2G 10min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC SAFETY STANDARDS(Note.7) UL879, UL1310, UL8750, CSA C22.2 No. 207-M89, TUV EN61347-1, EN61347-2-13 independent, TUV EN60950-1,CAN/CSA C22.2 No.223-M91(except for 48V), CAN/CSA C22.2 No. 250.13-12,GB19510.1,GB19510.14, IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950
WITHSTAND VOLTAGEI/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P:>100M Ohms/ 500VDC / 25°C / 70% RH
EMC EMISSIONCompliance to EN55015, EN55032 Class B, EN61000-3-2 Class C (≧75% load) ; EN61000-3-3,GB17743 and GB17625.1
EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV)
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25°C of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation.4. Derating may be needed under low input voltage. Please check the static characteristics for more details.5. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2.6. Please refer to “DRIVING METHODS OF LED MODULE”.7. Safety and EMC design refer to EN60958-1, subject 8750(UL), CNS15233, GB7000.1, FCC part 18.8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.