Description
This Mean Well LED Driver is ideally suitable for LED lighting and moving sign applications. With constant voltage design, it is capable of delivering 100watts output. It is fully encapsulated with IP67 level. Power input is world compatible and able to work with anywhere from 100 to 240 volts AC input. Each product is 100% full load burn-in-tested and can handle up to 300VAC surge input for 5 seconds. Over load, over voltage and short circuit protection is built in to ensure its reliability.
- TypeLED Driver
- StyleLED Driver
- Output ChannelSingle
- Constant voltage design
- Universal AC input/Full range
- Fully encapsulated with IP67 level (Note.8)
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Fully isolated plastic case
- 100% full load burn-in-test
- Suitable for LED lighting and moving sign applications(Note.7)
- Low cost, high reliability
MODEL | LPV-100-24 | |
OUTPUT | DC VOLTAGE | 24V |
RATED CURRENT | 4.3A | |
CURRENT RANGE | 0 ~ 4.2A | |
RATED POWER(max.) | 100.8W | |
RIPPLE & NOISE(max.) (Note.2) | 150mVp-p | |
VOLTAGE TOLERANCE (Note.3) | ±5.0% | |
LINE REGULATION | ±1.0% | |
LOAD REGULATION | ±2.0% | |
SETUP, RISE TIME(Note.6) | 2000ms, 25ms 230VAC2000ms, 25ms/115VAC | |
HOLD UP TIME(Typ.) | 50ms/230VAC 14ms/115VAC at full load | |
INPUT | VOLTAGE RANGE(Note.4) | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY(Typ.) | 88% | |
AC CURRENT(Typ.) | 2.2A/115VAC 1.2A/230VAC | |
INRUSH CURRENT(Typ.) | COLD START 75A(twidth=700μs measured at 50% Ipeak) at 230VAC | |
MAX. No. of PSUs on 16A CIRCUIT BREAKER | 2 units(circuit breaker of type B)/3 units(circuit breaker of type C) at 230VAC | |
LEAKAGE CURRENT | 0.25mA/240VAC | |
PROTECTION | OVERLOAD | 110% ~ 150% rated output power |
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 27.6 ~ 32.4V | |
Protection type: Shut off o/p voltage, re-power on to recover | ||
ENVIRONMENT | WORKING TEMP. | -25 ~ +70°C (Refer to “Derating Curve”) |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +80°C, 10 ~ 95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY & EMC | SAFETY STANDARDS | UL8750,CSA C22.2 No 250.13-12,UL879,CSA C22.2 No.207-M89,IP67 approved. Design refer to EN60950-1 |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC | |
ISOLATION RESISTANCE | I/P-O/P:>100M Ohms/ 500VDC / 25°C / 70% RH | |
EMC EMISSION | Compliance to EN55032 (CISPR32) Class B, EN61000-3-2 Class A(A(≤80% load), EN61000-3-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25°C of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation.4. Derating may be needed under low input voltage. Please check the static characteristics for more details.5. The power supply is considered a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-quality EMC Directive on the complete installation again.6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes. |