Description
This power supply is ideally suited for use with amplifier projects. The regulated 15VDC, 23.2A design is capable of delivering 350watts of output. Overload, over voltage, and over temperature protection is built-in, shutting down the power supply to prevent damage and then restoring power upon recovery.
- TypeAD/DC Power
- StyleEnclosed
- Output ChannelSingle
- AC input range selectable by switch
- Withstand 300VAC surge input for 5 second
- Protections: Short circuit / Overload / Over voltage/ Over temperature
- Forced air cooling by built-in DC fan
- Built-in cooling Fan ON-OFF control
- 1U low profile
- Withstand 5G vibration test
- LED indicator for power on
- No load power consumption<0.75W
- 100% full load burn-in test
- High operating temperature up to 70°C
- Operating altitude up to 5000 meters (Note.8)
- High efficiency, long life and high reliability
MODEL | LRS-350-15 | |
OUTPUT | DC VOLTAGE | 15V |
RATED CURRENT | 23.2A | |
CURRENT RANGE | 0 ~ 23.2A | |
RATED POWER | 348W | |
RIPPLE & NOISE(max.) (Note.2) | 150mVp-p | |
VOLTAGE ADJ. RANGE | 13.5 ~ 18V | |
VOLTAGE TOLERANCE (Note.3) | ±1.0% | |
LINE REGULATION (Note.4) | ±0.5% | |
LOAD REGULATION (Note.5) | ±0.5% | |
SETUP, RISE TIME | 1500ms, 50ms/230VAC 1500ms, 50ms/115VAC at full load | |
HOLD UP TIME(Typ.) | 16ms/230VAC 12ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 132VAC/ 180 ~ 264VDC by switch240 ~ 370VDC(switch on 230VAC) |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY(Typ.) | 86% | |
AC CURRENT(Typ.) | 6.8A/115VAC 3.4A/230VAC | |
INRUSH CURRENT(Typ.) | 60A/115VAC 60A/230VAC | |
LEAKAGE CURRENT | <2mA/240VAC | |
PROTECTION | OVERLOAD(Note.8) | 110 ~ 140% rated output power |
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 18 ~ 21V | |
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||
OVER TEMPERATURE | Hiccup mode, recovers automatically after fault condition is removed | |
FUNCTION | FAN ON/OFF CONTROL(Typ.) | RTH3≧50°C FAN ON, ≦40°C FAN OFF |
ENVIRONMENT | WORKING TEMP. | -25 ~ +70°C (Refer to “Derating Curve”) |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +85°C, 10 ~ 95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | |
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY | SAFETY STANDARDS | UL60950-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/ 500VDC / 25°C / 70% RH | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25°C of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation.4. Line regulation is measured from low line to high line at rated load.5. Load regulation is measured from 0% to 100% rated load.6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.7. The 150% peak load capability is built in for up to 1 second for 12~48V. LRS-350 will enter hiccup mode if the peak load is delivered for over 1 second and will recover once it resumes to the rated current level (115VAC/230VAC).8. The ambient temperature derating of 5°C/1000m is needed for operating altitude greater than 2000m (6500ft). |