Description
This power supply is ideally suited for use with amplifier projects. The regulated 5 VDC, 60A design is capable of delivering 350watts of output. Overload, over voltage, and over temperature protection is built-in, shutting down the power supply to prevent damage and then restoring power upon recovery.
- TypeAD/DC Power
- StyleEnclosed
- Output ChannelSingle
- AC input range selectable by switch
- Protections: Short circuit / Overload / Over voltage/Over temperature
- Forced air cooling by built-in DC fan
- Withstand 300vac surge input for 5 second
- Built-in cooling Fan ON-OFF control
- Built-in constant current limiting circuit
- 100% full load burn-in test
- LED indicator for power on
- Fixed switching frequency at 90KHz
- Low cost, high reliability
MODEL | NES-350-5 | |
OUTPUT | DC VOLTAGE | 5V |
RATED CURRENT | 60A | |
CURRENT RANGE | 0 ~ 60A | |
RATED POWER | 350W | |
RIPPLE & NOISE(max.) (Note.2) | 150mVp-p | |
VOLTAGE ADJ. RANGE | 4.5 ~ 5.6V | |
VOLTAGE TOLERANCE (Note.3) | ±3.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±2.0% | |
SETUP, RISE TIME | 1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at full load | |
HOLD UP TIME(Typ.) | 20ms/230VAC 16ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 90 ~ 132VAC/180 ~ 264VAC by switch 254 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY(Typ.) | 78% | |
AC CURRENT(Typ.) | 7A/115VAC 4A/230VAC | |
INRUSH CURRENT(Typ.) | 40A/115VAC 60A/230VAC | |
LEAKAGE CURRENT | <3.5mA/240VAC | |
PROTECTION | OVERLOAD | 105 ~ 135% rated output power |
Protection type: Constant current limiting, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 5.75 ~ 7.5V | |
Protection type: Shut down O/P voltage, re-power on to recover | ||
OVER TEMPERATURE | 95°C±5°C(3.3~7.5V);85°C±5°C(12~15V);80°C±5°C(24V);75°C±5°C (27~48V) (TSW1) Detect on case | |
Protection type: Shut down O/P voltage, recovers automatically after temperature goes down | ||
FUNCTION | FAN ON/OFF CONTROL(Typ.) | RTH2≧50°C FAN ON, ≦45°C FAN OFF (3.3 ~ 7.5V) |
RTH2≧55°C FAN ON, ≦50°C FAN OFF (12 ~ 48V) | ||
ENVIRONMENT | WORKING TEMP. | -20 ~ +60°C (Refer to output load derating curve) |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -20 ~ +85°C, 10 ~ 95%RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | |
VIBRATION | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY | SAFETY STANDARDS | UL60950-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C / 70% RH | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25°C of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation. |