Login
Sign up

Home /
Power Supply for Industrial Application /
AC/DC Switching Mode Power Supply for Industrial Application

Mean Well NES-25-5 5V 25W AC/DC Switching Power Supply[36]

★★★★★(102 recommends)

SKUPS-SP11221

16.90

Add To Cart
Buy Now

+

Description

This power supply is ideally suited for use with amplifier projects. The regulated 5 VDC, 5A design is capable of delivering 25watts of output. Overload, over voltage, and short circuit protection is built-in, shutting down the power supply to prevent damage and then restoring power upon recovery.

  • TypeAD/DC Power
  • StyleOpen Frame
  • Output ChannelSingle
  • Universal AC input/Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • 100% full load burn-in test
MODELNES-25-5
OUTPUTDC VOLTAGE5V
RATED CURRENT5A
CURRENT RANGE0 ~ 5A
RATED POWER25W
RIPPLE & NOISE(max.) (Note.2)80mVp-p
VOLTAGE ADJ. RANGE4.75 ~ 5.5V
VOLTAGE TOLERANCE (Note.3)±2.0%
LINE REGULATION (Note.4)±0.5%
LOAD REGULATION (Note.5)±0.5%
SETUP, RISE TIME500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME(Typ.)50ms/230VAC  10ms/115VAC at full load
INPUTVOLTAGE RANGE85 ~ 264VAC  120 ~ 370VDC
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY(Typ.)78%
AC CURRENT(Typ.)0.55A/115VAC  0.35A/230VAC
INRUSH CURRENT(Typ.)COLD START 45A
LEAKAGE CURRENT<2mA/240VAC
PROTECTIONOVERLOAD110 ~ 150% rated output power
Protection type: Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE5.75 ~ 6.75V
Protection type: Shut down o/p voltage, re-power on to recover
ENVIRONMENTWORKING TEMP.-20 ~ +60°C (Refer to “Derating Curve”)
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-40 ~ +85°C, 10 ~ 95%RH
TEMP. COEFFICIENT±0.03%/°C (0 ~ 45°C)
VIBRATION10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC(Note.7)SAFETY STANDARDS (Note.6)UL60950-1,CB(IEC60950-1),CCCGB4943.1:2011 approved
WITHSTAND VOLTAGEI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms/ 500VDC / 25℃/ 70% RH
EMC EMISSIONCompliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-1, light industry level, criteria A
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input,rated load and 25℃ of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12’’ twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation.4. Line regulation is measured from low line to high line at rated load.5. Load regulation is measured from 0% to 100% rated load.6. For the request of GB4943.1, the power supply is only suitable for use in the altitude 2000m below and the non tropical climate condition.7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)